+++ RoHS-konform +++ Remote ON/OFF Control: The power supply shall accept a logic collector level which will disable / enable all output voltage (excluding +5V standby). Temperature range: operating 0¢XC~50¢XC, storage -20¢XC ~ +80¢XC Temperature coefficient: 0.01% / ¢XC Transient response: output voltage recovers in less than 1 ms max. following a 25% load change Hold-up time: 17ms minimum at full load & nominal input voltage Dielectric withstand: input / output 1800 VAC for 1 second, input to frame ground 1800VAC for 1 second Input voltage : 90Vac ~ 265Vac Humidity: 5~95% RH Efficiency: 75% min., at full load Power good signal: turn-on delay 100 ms to 500 ms Overload protection: 150% max. Inrush current: 60A cold 90A ware at 132 VAC Over voltage protection: +5V, +3.3V, +12V1, +12V2 Dimension: 140L*150W*86H Unit: mm ohne Netzkabel